Skip to main navigation Skip to search Skip to main content

Bicuspid aortic valve: Inter-racial difference in frequency and aortic dimensions

  • Sonal Chandra
  • , Roberto M. Lang
  • , Jeremy Nicolarsen
  • , Etienne Gayat
  • , Kirk T. Spencer
  • , Victor Mor-Avi
  • , Marion A. Hofmann Bowman

Research output: Contribution to journalArticlepeer-review

65 Scopus citations

Abstract

Objectives: The objective of this study was to examine the similarities and differences in Caucasian (C) and African-American (AA) patients with bicuspid aortic valve (BAV) with respect to morphology, severity of aortic stenosis/insufficiency, and aortic dilation. Background: BAV is a common congenital valve abnormality, accounting for a large number of valve replacements. Methods: A total of 229 patients with the diagnostic code BAV were identified retrospectively from our computerized adult echocardiographic database, which consists of 91,896 studies performed at the University of Chicago Medical Center from 1998 to 2009, representing 40,878 patients. Of those, 183 patients with BAV were included in this retrospective BAV single-center cohort study and reanalyzed with a comprehensive assessment of aortic dimensions, aortic valve morphology and function, clinical cardiovascular risk factors, and patient characteristics. Results: Of the 183 patients with BAV, 138 were C and 45 were AA. Our echocardiographic database encompasses approximately 65% AA, 31% C, and 4% other races, for an estimated frequency of BAV in AA patients of 0.17% and a frequency in C patients of 1.1% (p = 0.001). There were no significant inter-racial differences regarding sex, height, weight, hyperlipidemia, diabetes, tobacco use, cardiac medications, and left ventricular ejection fraction. The AA cohort was older (age 50 ± 17 years vs. 43 ± 17 years, p < 0.05) and had a higher prevalence of hypertension (51% vs. 24%, p < 0.05). After adjusting for comorbidities, aortic dimensions were larger in C (C vs. AA: annulus, 2.4 ± 0.4 vs. 2.1 ± 0.4 cm; sinuses of Valsalva, 3.4 ± 0.7 vs. 3.1 ± 0.6 cm; sinotubular junction, 3.0 ± 0.6 vs. 2.6 ± 0.5 cm; and ascending aorta, 3.5 ± 0.7 vs. 3.2 ± 0.5 cm; all p values <0.05). Conclusions: This is the first study to report racial differences among patients with BAV with reduced aortic dimensions in AA patients despite the presence of more risk factors, suggestive of marked heterogeneity in the BAV population and indicating race as a potential disease modifier in BAV.

Original languageEnglish
Pages (from-to)981-989
Number of pages9
JournalJACC: Cardiovascular Imaging
Volume5
Issue number10
DOIs
StatePublished - Oct 2012

Keywords

  • aortopathy
  • bicuspid aortic valve
  • thoracic aortic aneurysm and dissection

Fingerprint

Dive into the research topics of 'Bicuspid aortic valve: Inter-racial difference in frequency and aortic dimensions'. Together they form a unique fingerprint.

Cite this