Skip to main navigation Skip to search Skip to main content

Bioactive versus bare platinum coils in the treatment of intracranial aneurysms: The MAPS (Matrix and Platinum Science) trial

  • Cameron G. McDougall
  • , S. Claiborne Johnston
  • , A. Gholkar
  • , S. L. Barnwell
  • , J. C. Vazquez Suarez
  • , J. Massó Romero
  • , J. C. Chaloupka
  • , A. Bonafe
  • , A. K. Wakhloo
  • , D. Tampieri
  • , C. F. Dowd
  • , A. J. Fox
  • , S. J. Imm
  • , K. Carroll
  • , A. S. Turk

Research output: Contribution to journalArticlepeer-review

121 Scopus citations

Abstract

BACKGROUND AND PURPOSE: The ability of polymer-modified coils to promote stable aneurysm occlusion after endovascular treatment is not well-documented. Angiographic aneurysm recurrence is widely used as a surrogate for treatment failure, but studies documenting the correlation of angiographic recurrence with clinical failure are limited. This trial compares the effectiveness of Matrix2 polyglycolic/polylactic acid biopolymer-modified coils with bare metal coils and correlates the angiographic findings with clinical failure (ie, target aneurysm recurrence), a composite end point that includes any incident of posttreatment aneurysm rupture, retreatment, or unexplained death. MATERIALSANDMETHODS: This was a multicenter randomized noninferiority trial with blinded end point adjudication.Weenrolled 626 patients, divided between Matrix2 and bare metal coil groups. The primary outcome was target aneurysm recurrence at 12 ± 3 months. RESULTS: At 455 days, at least 1 target aneurysm recurrence event had occurred in 14.6% of patients treated with bare metal coils and 13.3% of Matrix2 (P=.76, log-rank test) patients; 92.8% of target aneurysm recurrence events were re-interventions for aneurysms that had not bled after treatment, and 5.8% of target aneurysm recurrence events resulted from hemorrhage or rehemorrhage, with or without retreatment. Symptomatic re-intervention occurred in only 4 (0.6%) patients. At 455 days, 95.8% of patients with unruptured aneurysms and 90.4% of those with ruptured aneurysms were independent (mRS ≤ 2). Target aneurysm recurrence was associated with incomplete initial angiographic aneurysm obliteration, presentation with rupture, and a larger aneurysmal dome and neck size. CONCLUSIONS: Tested Matrix2 coils were not inferior to bare metal coils. Endovascular coiling of intracranial aneurysms was safe, and the rate of technical success was high. Target aneurysm recurrence is a promising clinical outcome measure that correlates well with established angiographic measurements.

Original languageEnglish
Pages (from-to)935-942
Number of pages8
JournalAmerican Journal of Neuroradiology
Volume39
Issue number5
DOIs
StatePublished - May 2014

Fingerprint

Dive into the research topics of 'Bioactive versus bare platinum coils in the treatment of intracranial aneurysms: The MAPS (Matrix and Platinum Science) trial'. Together they form a unique fingerprint.

Cite this