Skip to main navigation Skip to search Skip to main content

Bone densitometry worldwide: a global survey by the ISCD and IOF

  • on behalf of the International Society for Clinical Densitometry (ISCD) and the International Osteoporosis Foundation (IOF)

Research output: Contribution to journal › Article › peer-review

61 Scopus citations

Abstract

Summary: In a global survey of fracture liaison services, most reported that DXA access met needs. However, adherence to basic DXA quality and reporting procedures was confirmed by only around 50% of institutions and many required education for operators/interpreters. Overall, there is significant variability in the access to, and quality of, DXA services worldwide. Introduction: While the use of dual-energy X-ray absorptiometry (DXA) has been widely adopted worldwide for the assessment of bone mineral density, the quality of DXA facilities is unknown. To address this, a global survey of fracture liaison services (FLS) was conducted by the International Society for Clinical Densitometry (ISCD) and the International Osteoporosis Foundation (IOF) to assess the quality of their DXA facilities. Methods: A questionnaire for the accessibility and quality of DXA services was co-created by representatives of the ISCD and the IOF and made available to institutions who participated in the Capture the Fracture Best Practice Framework. From a list of 331 contacted invitees, 124 FLS centres responded; analyses were based on 121 centres with suitable data. Results: Over 70% of institutions reported that, for over 90% of the time, DXA access met service needs, and the scanning/reporting quality was perceived as excellent. However, 25% of DXA facilities reported not being accredited by a professional/governmental organization, and adherence to some basic DXA quality assurance and reporting procedures was confirmed by < 50% of services. Importantly, in excess of 50% of institutions stated that they desired ongoing education in osteoporosis and DXA for operators and interpreters. Conclusion: There is significant variability in the access to and quality of DXA services for established FLS worldwide. Despite two decades of training initiatives in osteoporosis densitometry, many centres are falling short of the standards of the IOF-ISCD Osteoporosis Essentials criteria.

Original languageEnglish
Pages (from-to)1779-1786
Number of pages8
JournalOsteoporosis International
Volume31
Issue number9
DOIs
StatePublished - Sep 1 2020

Keywords

  • Bone densitometry
  • Dual-energy X-ray absorptiometry
  • Epidemiology
  • Fracture liaison services
  • Osteoporosis
  • Quality standards

Fingerprint

Dive into the research topics of 'Bone densitometry worldwide: a global survey by the ISCD and IOF'. Together they form a unique fingerprint.

Cite this