Comparison of 26-mm Evolut and 23-mm Sapien 3 Valves in TAVR for Small Aortic Annulus

Ruyun Jin, Emily J. Cox, Branden R. Reynolds, Brydan D. Curtis, Robert W. Hodson, Michael C. Reed, Sameer A. Gafoor, Gary L. Grunkemeier, Matthew D. Forrester, Michael E. Ring

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Background. Patients with small aortic annuli (SAA) are prone to higher post-transcatheter aortic valve replacement (TAVR) transvalvular gradients and development of prosthesis-patient mismatch (PPM). In many patients with SAA, the choice of TAVR valve commonly involves choosing between the 26-mm Medtronic Evolut 2 (ME26) or the 23-mm Edwards Sapien 3 valve (ES23). We compared echocardiographic and clinical outcomes in patients with SAA undergoing TAVR with either valve. Methods. We queried the Providence St. Joseph Health Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry database for patients undergoing TAVR with either the ES23 or ME26 between July 2015 and December 2018 at 11 hospitals. Post-TAVR echocardiographic and clinical results in-hospital, at 1 month, and at 1 year were examined. High gradient (HG) was defined as mean gradient (MG) ≥20 mm Hg. Results. We identified 1162 patients with SAA undergoing TAVR with either the ME26 (n = 233) or ES23 valve (n = 929). Baseline characteristics between groups were similar. At 1 month, the ME26 was associated with a lower MG than the ES23 (7.7 ± 4.7 mm Hg vs 13.1 ± 4.9 mm Hg; P<.001) and moderate or severe PPM (11% and 3% vs 27% and 13%; P<.001). Occurrence of HG at 1 year was lower with the ME26 valve vs the ES23 valve (0% vs 15%; P<.001). In-hospital and follow-up clinical outcomes to 1 year were similar for both groups. Conclusion. TAVR in SAA with the ME26 is associated with lower incidence of HG or PPM compared with the ES23. While clinical outcomes at 1 year were similar, the long-term implications of these findings remain unknown.

Original languageEnglish
Pages (from-to)E433-E441
JournalJournal of Invasive Cardiology
Volume34
Issue number6
DOIs
StatePublished - Jun 2022
Externally publishedYes

Keywords

  • TAVR
  • prosthesis-patient mismatch
  • small aortic annulus
  • surgical outcomes
  • transcatheter aortic valve replacement

Fingerprint

Dive into the research topics of 'Comparison of 26-mm Evolut and 23-mm Sapien 3 Valves in TAVR for Small Aortic Annulus'. Together they form a unique fingerprint.

Cite this