Determining the minimum discard volume for central venous catheter blood draws

Research output: Contribution to journal › Article › peer-review

19 Scopus citations

Abstract

This study aimed to determine the minimum discard volume from central venous catheters (CVCs) to avoid dilution or contamination from flush or IV fluids. In 93 adult patients with CVCs, minimum discard volume findings were 9 ml for tunneled and 6 ml for nontunneled catheters. Nurses who obtain samples from CVCs are uniquely positioned to minimize blood loss from sampling.

Original languageEnglish
Pages (from-to)454-458
Number of pages5
JournalClinical journal of oncology nursing
Volume16
Issue number5
DOIs
StatePublished - Oct 2012

Fingerprint

Dive into the research topics of 'Determining the minimum discard volume for central venous catheter blood draws'. Together they form a unique fingerprint.