Abstract
AIMS: Despite well-known gender differences in heart failure, it is unknown if clinical markers and symptoms differ between women and men after left ventricular assist device (LVAD) implantation. Our aim was to examine gender differences in trajectories of clinical markers (echocardiographic markers and plasma biomarkers) and symptoms from pre- to post-LVAD implantation.
METHODS AND RESULTS: This was a secondary analysis of data collected from a study of patients from pre- to 1, 3, and 6 months post-LVAD implantation. Data were collected on left ventricular internal end-diastolic diameter (LVIDd) and ejection fraction (LVEF), plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP), and soluble suppressor of tumorigenicity (sST2). Physical and depressive symptoms were measured using the Heart Failure Somatic Perception Scale and Patient Health Questionnaire-9, respectively. Latent growth curve modelling was used to compare trajectories between women and men. The average age of the sample (n = 98) was 53.3 ± 13.8 years, and most were male (80.6%) and had non-ischaemic aetiology (65.3%). Pre-implantation, women had significantly narrower LVIDd (P
CONCLUSION: Trajectories of clinical markers differed somewhat between women and men, but trajectories of symptoms were similar, indicating some physiologic but not symptomatic gender differences in response to LVAD.
| Original language | American English |
|---|---|
| Journal | European journal of cardiovascular nursing : journal of the Working Group on Cardiovascular Nursing of the European Society of Cardiology |
| State | Published - Jun 3 2021 |
Fingerprint
Dive into the research topics of 'Exploring gender differences in trajectories of clinical markers and symptoms after left ventricular assist device implantation.'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver