Skip to main navigation Skip to search Skip to main content

Femoral Component Revision Using a 2nd Generation Modular Femoral Implant

  • Puneet K. Bhatia
  • , Steven L. Barnett
  • , Timothy P. Lovell
  • , William J. Hozack
  • , Arthur L. Malkani

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

The purpose of this prospective multicenter study was to evaluate results of 122 revision THAs using a 2nd generation modular femoral implant in 120 patients. Majority of cases had significant femoral bone loss. HHS improved from a pre-operative mean score of 46 to 88 points, and SF-36 scores improved from 31 to 44 points at 2- to 5-year follow-up. There were 18 cases of intraoperative fractures of which 10 were femur shaft, 7 trochanteric, and 1 acetabular. Dislocation incidence was 9% and overall survivorship at 5. years was 97%. Use of modular femoral implants provides versatility and simplification to restore stability, limb length and offset in patients undergoing femoral component revision, Additional steps need to be undertaken to minimize incidence of fracture and dislocation.

Original languageEnglish
Pages (from-to)1397-1402
Number of pages6
JournalJournal of Arthroplasty
Volume30
Issue number8
DOIs
StatePublished - Aug 1 2015

Keywords

  • Dislocation following revision THA
  • Femoral bone loss
  • Intraoperative fracture
  • Modular femoral implant
  • Revision THA

Fingerprint

Dive into the research topics of 'Femoral Component Revision Using a 2nd Generation Modular Femoral Implant'. Together they form a unique fingerprint.

Cite this