Skip to main navigation Skip to search Skip to main content

Outcomes Following Transcatheter Aortic Valve Replacement for Degenerative Stentless Versus Stented Bioprostheses

  • Alison Duncan
  • , Neil Moat
  • , Matheus Simonato
  • , Arend de Weger
  • , Jorg Kempfert
  • , Holger Eggebrecht
  • , Antony Walton
  • , Farrel Hellig
  • , Ran Kornowski
  • , Konstantinos Spargias
  • , Oscar Mendiz
  • , Raj Makkar
  • , Mayra Guerrero
  • , Charanjit Rihal
  • , Isaac George
  • , Creighton Don
  • , Alessandro Iadanza
  • , Vinayak Bapat
  • , Robert Welsh
  • , Harindra C. Wijeysundera
  • David Wood, Janarthanan Sathananthan, Haim Danenberg, Francesco Maisano, Santiago Garcia, Sameer Gafoor, Luis Nombela-Franco, Javier Cobiella, Danny Dvir

Research output: Contribution to journalArticlepeer-review

72 Scopus citations

Abstract

Objectives: A large comprehensive analysis of transcatheter aortic valve replacement (TAVR) was performed for failed stentless bioprostheses. Background: Valve-in-valve (ViV) transcatheter aortic replacement (TAVR) is an alternative to redo surgery for patients with a failing aortic bioprosthesis. Methods: Unadjusted outcome data were collected from the VIVID (Valve-in-Valve International Data) registry between 2007 and 2016 from a total of 1,598 aortic ViV procedures (291 stentless, 1,307 stented bioprostheses). Results: Bioprosthetic failure was secondary to aortic regurgitation in 56% of stentless and 20% stented devices (p < 0.001). ViV-TAVR access was transfemoral in 71.1% stentless and 74.2% stented ViV-TAVR. Self-expanding devices were more frequently used in stentless ViV-TAVR (56.0% vs. 39.9%; p = 0.05), but there was no difference between balloon-expanding and self-expanding TAVR devices for stented ViV-TAVR (48.6% vs. 45.1%). The degree of oversizing for all mechanisms of bioprosthesis failure was 9 ± 10% for stentless ViV-TAVR vs. 6 ± 9% for stented ViV-TAVR (and 8 ± 10% for stentless ViV-TAVR vs. 3 ± 9% for stented ViV-TAVR in patients with predominant aortic regurgitation; both p < 0.001). Initial device malposition (10.3% vs. 6.2%; p = 0.014), second transcatheter device (7.9% vs. 3.4%), coronary obstruction (6.0% vs. 1.5%), and paravalvular leak occurred more frequently in stentless ViV-TAVR (all p < 0.001). Hospital stay duration (median 7 days) was no different, and 30-day (6.6% vs. 4.4%; p = 0.12) and 1-year mortality year (15.8% vs. 12.6%; p = 0.15) were numerically higher, but not statistically different, after stentless ViV-TAVR. Conclusions: Stentless ViV-TAVR is associated with greater periprocedural complications (initial device malposition, second transcatheter device, coronary obstruction, paravalvular leak), but no difference in 30-day and 1-year outcome.

Original languageEnglish
Pages (from-to)1256-1263
Number of pages8
JournalJACC: Cardiovascular Interventions
Volume12
Issue number13
DOIs
StatePublished - Jul 8 2019

Keywords

  • stented bioprostheses
  • stentless bioprostheses
  • transcatheter aortic valve replacement
  • valve-in-valve

Fingerprint

Dive into the research topics of 'Outcomes Following Transcatheter Aortic Valve Replacement for Degenerative Stentless Versus Stented Bioprostheses'. Together they form a unique fingerprint.

Cite this