Skip to main navigation Skip to search Skip to main content

Percutaneous Tricuspid Valve Regurgitation Repair with the MitraClip Device Using an Edge-to-Edge Bicuspidization Technique

  • Sameer Gafoor
  • , O. Madalina Petrescu
  • , Eric J. Lehr
  • , Charles Puls
  • , Ming Zhang
  • , John L. Petersen
  • , John V. Olsen
  • , Irina Penev
  • , Mayank Agrawal
  • , Rahul Sharma
  • , Glenn Barnhart

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.

Original languageEnglish
Pages (from-to)E30-E36
JournalJournal of Invasive Cardiology
Volume29
Issue number3
StatePublished - Mar 2017

Keywords

  • edge-to-edge leaflet repair
  • mitral valve repair
  • tricuspid valve repair

Fingerprint

Dive into the research topics of 'Percutaneous Tricuspid Valve Regurgitation Repair with the MitraClip Device Using an Edge-to-Edge Bicuspidization Technique'. Together they form a unique fingerprint.

Cite this