TY - JOUR
T1 - Safety and efficiency of percutaneous coronary intervention using a standardised optical coherence tomography workflow
AU - behalf of the LightLab Initiative Investigators
AU - Osborn, Eric A.
AU - Johnson, Michael
AU - Maksoud, Aziz
AU - Spoon, Daniel
AU - Zidar, Frank J.
AU - Korngold, Ethan C.
AU - Buccola, Jana
AU - Cabrera, Hector Garcia
AU - Rapoza, Richard J.
AU - West, Nick E.J.
AU - Rauch, Judah
N1 - Publisher Copyright:
© Europa Digital & Publishing 2023. All rights reserved.
PY - 2023/2
Y1 - 2023/2
N2 - Background: While intravascular imaging guidance during percutaneous coronary intervention (PCI) improves outcomes, routine intravascular imaging usage remains low, in part due to perceived inefficiency and safety concerns. Aims: The LightLab (LL) Initiative was designed to evaluate whether implementing a standardised optical coherence tomography (OCT) workflow impacts PCI safety metrics and procedural efficiency. Methods: In this multicentre, prospective, observational study, PCI procedural data were collected over 2 years from 45 physicians at 17 US centres. OCT-guided PCI incorporating the LL workflow (N=264), a structured algorithm using routine pre- and post-PCI OCT imaging, was compared with baseline angiography-only PCI (angio) (N=428). Propensity score analysis identified 207 matched procedures. Outcomes included procedure time, radiation exposure, contrast volume, device utilisation, and treatment strategy. Results: Compared with angiography alone, LL workflow OCT-guided PCI increased the median procedural time by 9 minutes but reduced vessel preparation time (2 min LL workflow vs 3 min angio; p<0.001) and resulted in less unplanned additional treatment (4% LL workflow vs 10% angio; p=0.01). With LL workflow OCT guidance, fewer cineangiography views were needed compared to angiography guidance, leading to decreased radiation exposure (1,133 mGy LL workflow vs 1,269 mGy angio; p=0.02), with no difference in contrast utilisation between groups (p=0.28). Furthermore, LL workflow OCT guidance resulted in fewer predilatation balloons and stents being used, more direct stent placement, and greater stent post-dilatation than angiography-guided PCI. Conclusions: The incorporation of a standardised pre- and post-PCI OCT imaging workflow improves procedural efficiency and safety metrics, at a cost of a modestly longer procedure time.
AB - Background: While intravascular imaging guidance during percutaneous coronary intervention (PCI) improves outcomes, routine intravascular imaging usage remains low, in part due to perceived inefficiency and safety concerns. Aims: The LightLab (LL) Initiative was designed to evaluate whether implementing a standardised optical coherence tomography (OCT) workflow impacts PCI safety metrics and procedural efficiency. Methods: In this multicentre, prospective, observational study, PCI procedural data were collected over 2 years from 45 physicians at 17 US centres. OCT-guided PCI incorporating the LL workflow (N=264), a structured algorithm using routine pre- and post-PCI OCT imaging, was compared with baseline angiography-only PCI (angio) (N=428). Propensity score analysis identified 207 matched procedures. Outcomes included procedure time, radiation exposure, contrast volume, device utilisation, and treatment strategy. Results: Compared with angiography alone, LL workflow OCT-guided PCI increased the median procedural time by 9 minutes but reduced vessel preparation time (2 min LL workflow vs 3 min angio; p<0.001) and resulted in less unplanned additional treatment (4% LL workflow vs 10% angio; p=0.01). With LL workflow OCT guidance, fewer cineangiography views were needed compared to angiography guidance, leading to decreased radiation exposure (1,133 mGy LL workflow vs 1,269 mGy angio; p=0.02), with no difference in contrast utilisation between groups (p=0.28). Furthermore, LL workflow OCT guidance resulted in fewer predilatation balloons and stents being used, more direct stent placement, and greater stent post-dilatation than angiography-guided PCI. Conclusions: The incorporation of a standardised pre- and post-PCI OCT imaging workflow improves procedural efficiency and safety metrics, at a cost of a modestly longer procedure time.
KW - coronary
KW - efficiency
KW - imaging
KW - intervention
KW - intravascular
KW - optical coherence
KW - percutaneous
KW - safety
KW - tomography
UR - http://www.scopus.com/inward/record.url?scp=85148725811&partnerID=8YFLogxK
U2 - 10.4244/EIJ-D-22-00512
DO - 10.4244/EIJ-D-22-00512
M3 - Article
C2 - 36373421
AN - SCOPUS:85148725811
SN - 1774-024X
VL - 18
SP - 1178
EP - 1187
JO - EuroIntervention
JF - EuroIntervention
IS - 14
ER -