TY - GEN
T1 - The real-time dose measurement scintillating fiber array for intravascular brachytherapy procedures
AU - Guèye, Paul
AU - Harmon, Chad
AU - Tynes, Lawrence
AU - Keppel, Cynthia
AU - Kieper, Douglas
AU - Onumah, Nnenna
AU - Wong, Ping
PY - 2003
Y1 - 2003
N2 - Intravascular Brachytherapy using catheter based high dose rate β sources has taken nowadays an important role in interventional cardiology to combat in-stent restenosis following percutaneous transluminal coronary angioplasty. At the present time, there is no detector system which can record accurate quantitative doses and spatial information in real time for intravascular brachytherapy. This is partially because of the short-range of the low energy beta emission of 32P (average energy of 690 keV) and 90Sr/90Y (average energy of 930 keV) and the resolution limitation of existing extrapolation chambers and radiochromatic-dye films (currently the preferred method used). However, relatively high non-uniformity, which occurs at the stepping region due to excessive gapping or overlapping between steps, might result in instent restenosis or detrimental to the coronary vascular structure due to significant discrepancies between prescribed and delivered doses. We have developed a Scintillating Fiber Based Beta Detector prototype which will permit: (i) extracting in real time of accurate dose measurements of the radioactive emitter in 2D or 3D; (ii) address the junction/stepping problem in a reliable fashion; (iii) allow extraction of information on the (in)homogeneity of the radioactive source (if any); and (iv) provide a quick feedback to radio-therapists for a fast re-adjustment of the radiation exposure for patient treatments. It is composed of an array of 3 × 3 mm2 scintillating fibers optically coupled to photo-multiplier tubes for photon-to-current conversion. A CAMAC LabView based data acquisition system is used for data collection, histogramming and data analysis. A Geant4 Monte Carlo simulation was also specially developed for this detector to provide the necessary tool to investigate the various capabilities of such devices.
AB - Intravascular Brachytherapy using catheter based high dose rate β sources has taken nowadays an important role in interventional cardiology to combat in-stent restenosis following percutaneous transluminal coronary angioplasty. At the present time, there is no detector system which can record accurate quantitative doses and spatial information in real time for intravascular brachytherapy. This is partially because of the short-range of the low energy beta emission of 32P (average energy of 690 keV) and 90Sr/90Y (average energy of 930 keV) and the resolution limitation of existing extrapolation chambers and radiochromatic-dye films (currently the preferred method used). However, relatively high non-uniformity, which occurs at the stepping region due to excessive gapping or overlapping between steps, might result in instent restenosis or detrimental to the coronary vascular structure due to significant discrepancies between prescribed and delivered doses. We have developed a Scintillating Fiber Based Beta Detector prototype which will permit: (i) extracting in real time of accurate dose measurements of the radioactive emitter in 2D or 3D; (ii) address the junction/stepping problem in a reliable fashion; (iii) allow extraction of information on the (in)homogeneity of the radioactive source (if any); and (iv) provide a quick feedback to radio-therapists for a fast re-adjustment of the radiation exposure for patient treatments. It is composed of an array of 3 × 3 mm2 scintillating fibers optically coupled to photo-multiplier tubes for photon-to-current conversion. A CAMAC LabView based data acquisition system is used for data collection, histogramming and data analysis. A Geant4 Monte Carlo simulation was also specially developed for this detector to provide the necessary tool to investigate the various capabilities of such devices.
UR - https://www.scopus.com/pages/publications/11844302192
U2 - 10.1109/nssmic.2003.1352240
DO - 10.1109/nssmic.2003.1352240
M3 - Conference contribution
AN - SCOPUS:11844302192
SN - 0780382579
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 1855
EP - 1859
BT - 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2003 Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2003
Y2 - 19 October 2003 through 25 October 2003
ER -