The real-time dose measurement scintillating fiber array for intravascular brachytherapy procedures

  • Paul Guèye
  • , Chad Harmon
  • , Lawrence Tynes
  • , Cynthia Keppel
  • , Douglas Kieper
  • , Nnenna Onumah
  • , Ping Wong

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

1 Scopus citations

Abstract

Intravascular Brachytherapy using catheter based high dose rate β sources has taken nowadays an important role in interventional cardiology to combat in-stent restenosis following percutaneous transluminal coronary angioplasty. At the present time, there is no detector system which can record accurate quantitative doses and spatial information in real time for intravascular brachytherapy. This is partially because of the short-range of the low energy beta emission of 32P (average energy of 690 keV) and 90Sr/90Y (average energy of 930 keV) and the resolution limitation of existing extrapolation chambers and radiochromatic-dye films (currently the preferred method used). However, relatively high non-uniformity, which occurs at the stepping region due to excessive gapping or overlapping between steps, might result in instent restenosis or detrimental to the coronary vascular structure due to significant discrepancies between prescribed and delivered doses. We have developed a Scintillating Fiber Based Beta Detector prototype which will permit: (i) extracting in real time of accurate dose measurements of the radioactive emitter in 2D or 3D; (ii) address the junction/stepping problem in a reliable fashion; (iii) allow extraction of information on the (in)homogeneity of the radioactive source (if any); and (iv) provide a quick feedback to radio-therapists for a fast re-adjustment of the radiation exposure for patient treatments. It is composed of an array of 3 × 3 mm2 scintillating fibers optically coupled to photo-multiplier tubes for photon-to-current conversion. A CAMAC LabView based data acquisition system is used for data collection, histogramming and data analysis. A Geant4 Monte Carlo simulation was also specially developed for this detector to provide the necessary tool to investigate the various capabilities of such devices.

Original languageEnglish
Title of host publication2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1855-1859
Number of pages5
ISBN (Print)0780382579
DOIs
StatePublished - 2003
Externally publishedYes
Event2003 Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2003 - Portland, OR, United States
Duration: Oct 19 2003 → Oct 25 2003

Publication series

NameIEEE Nuclear Science Symposium Conference Record
Volume3
ISSN (Print)1095-7863

Conference

Conference2003 Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2003
Country/TerritoryUnited States
CityPortland, OR
Period10/19/03 → 10/25/03

Fingerprint

Dive into the research topics of 'The real-time dose measurement scintillating fiber array for intravascular brachytherapy procedures'. Together they form a unique fingerprint.

Cite this