Skip to main navigation Skip to search Skip to main content

When Experts Fail: Use of a Short Turning Radius Colonoscope Facilitates Successful Completion of Colonoscopy in Patients with Bowel Fixity

  • Mohit Girotra
  • , Saurabh Sethi
  • , Monique T. Barakat
  • , Robert J. Huang
  • , Shai Friedland
  • , Uri Ladabaum
  • , Subhas Banerjee

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Background: Rates of incomplete colonoscopy in non-expert settings range up to 13%. Expert colonoscopists can complete ~ 95% colonoscopies when other endoscopists fail; however, a small number remain incomplete even in expert hands, typically due to bowel fixity. Aims: Pentax Retroview™ (EC-3490TLi) is a new slim colonoscope with a short turning radius (STR) and greater tip deflection (210°), which allows easy maneuverability across sharply angulated/fixed colonic bends. We evaluated the utility of this colonoscope for completing colonoscopies that fail even in the hands of expert colonoscopists. Methods: Retrospective chart review was performed, and main outcomes measured included cecal intubation rate, lesions detected, dosage of sedation used, and complications. Results: Using the STR colonoscope, complete colonoscopy to the cecum was possible in 34/37 patients (91.9%). No loss of lumen/blind advancement was necessary in any of the procedures. No adverse events occurred. Among the completed colonoscopies, 6/34 (17.6%) patients had adenomas, all proximal to the site of prior failure, including one advanced adenoma. All failures (n = 3, 8.1%) had a history of cancer surgeries, with peritoneal carcinomatosis/extensively fixed/frozen bowel (two patients) and an additional diverticular stricture with colo-vesical fistula (one patient). Conclusion: STR colonoscope facilitates completion of a high proportion (91.9%) of colonoscopies that previously failed in expert hands. Its STR allows easy maneuverability across segments of sharp angulation with bowel fixity without need for blind advancement. The use of this colonoscope led to the detection of adenomas in 17.6% of patients, all proximal to the site of prior failed colonoscopy.

Original languageEnglish
Pages (from-to)1429-1435
Number of pages7
JournalDigestive Diseases and Sciences
Volume65
Issue number5
DOIs
StatePublished - May 1 2020

Keywords

  • Colon cancer
  • Colonoscope retroflexion
  • Failed colonoscopy
  • Incomplete colonoscopy
  • New colonoscope
  • Short turning radius colonoscope

Fingerprint

Dive into the research topics of 'When Experts Fail: Use of a Short Turning Radius Colonoscope Facilitates Successful Completion of Colonoscopy in Patients with Bowel Fixity'. Together they form a unique fingerprint.

Cite this